Internal Sinus Lift using SynthoGraft™ and Restoration with a CAD/CAM IAC®
This video demonstrates the simultaneous bone grafting of a large buccal defect and placement of a 5.0 x 6.0mm Bicon Integra-CP™ Implant with an internal sinus lift procedure using SynthoGraft™ and a sinus lift abutment, as well as the implant’s restoration with a CAD/CAM fabricated Integrated Abutment Crown™ in only three clinical visits. |
|
---|---|
Placement of a Bicon SHORT® Implant using a Floor Transport Technique
On April 5, 2011, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included the placement of a 6.0 x 5.7mm Bicon SHORT® Implant using a Floor Transport Technique. |
|
Placement of a Bicon SHORT® Implant using a Floor Transport Technique and the Uncovering of Two Bicon SHORT® Implants
On October 15, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher and Doctor Vincent Morgan to practitioners around the world. The demonstration included two cases. The first case was the placement of a 6.0 x 5.7mm Bicon SHORT® Implant using a Floor Transport Technique. The second case was the uncovering of two Bicon SHORT® Implants. |
|
Placement of Three Bicon SHORT® Implants using Internal Sinus Lifts and the Insertion of an Integrated Abutment Crown™
On September 21, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher and Dr. Rainier Urdaneta to practitioners around the world. The demonstration included two cases. The first case was the placement of a 4.0 x 5.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique and the placement of a 5.0 x 5.0mm and a 6.0 x 5.0mm Bicon SHORT® Implant using Internal Sinus Lifts. The second case was the insertion of an Integrated Abutment Crown™. |
|
Placement of Bicon SHORT® Implants after a Ridge Split, Uncovering of Two Bicon SHORT® Implants, and Placement of a Bicon SHORT® Implant Using an Internal Sinus Lift
On May 28, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to Bicon practitioners. The demonstration included three cases. The first case was the placement of two 4.5 x 6.0mm Bicon SHORT® Implant after a Ridge Split. The second case was an uncovering of two Bicon SHORT® Implants. The third case was the placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an Internal Sinus Lift Technique using SynthoGraft™. |
|
Lateral Sinus Lift using SynthoGraft™
On May 6, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included a lateral sinus lift using SynthoGraft™. |
|
Placement of a Bicon SHORT® Implant Using an Internal Sinus Lift and SynthoGraft™
On February 18, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included the placement of a 6.0 x 5.0mm Bicon SHORT® Implant using an internal sinus lift and SynthoGraft™. |
|
Placement of Two Bicon SHORT® Implants, One with an Internal Sinus Lift Using SynthoGraft™
On December 17th, 2009, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included the placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an Internal Sinus Lift using SynthoGraft™, accompanied by the placement of 5.0 x 6.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique. |
|
Placement of Two Bicon SHORT® Implants
On October 28th, 2009, Bicon presented a two-way internet telecast presentation and live demonstration by Doctor Shadi Daher to Bicon practitioners at the Tver State Medical Academy in Russia. The demonstration included the placement of a 4.5 x 6.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique, accompanied by the placement of a 5.0 x 6.0mm Bicon SHORT® Implant using an Internal Sinus Lift. |
|
Placement of a Bicon SHORT® Implant using an Internal Sinus Lift and SynthoGraft™
On September 25th , 2009, Bicon presented an internet telecast presentation and live demonstration by Doctor Shadi Daher to Bicon practitioners in London. The demonstration included the placement of a 6.0 x 5.0mm Bicon SHORT® Implant using an Internal Sinus Lift and SynthoGraft™. |